Loading...
HomeMy WebLinkAboutYellowstone Center Bldg 1 - Fire Service Line w a q v Z fr NNW J •� GRAPHIC SCALE Lu c- 10 0 5 10 EXISTI BUILDING EL 10t � 11 1a YELLOWSTONE CENTER EX WALL WALL a 1�coOegestj � - - BUILDING 1 / MC BLDC ( IN FEET) (1123 RESEARCH DRIVE) 24'X47' 0 3 1 inch = 10 [t °' BUILDING MD T°0. EXTG. SLAB ADDITION I T NE -Y4" R SE V. ELE` 4858.5 WARNING �i EXT . WA 0 \ SER V. CURB STOP EXTG " WATER SERVICE 2$s8 - Brane (ABANDONED BE EN NEWCONNECTIONS EX G. FIRESERVIC EXTG. OS&YJ - ----- -ONNE-----�---------- ___- PROJECT R F T M BAR DOES ---------------------- rr ---- -- - --- '-.$A - - alY sfs Dr NOT MEASURE 1" VALVE j r SITE e^p� THEN DRAWING IS EXTG FI SERVICE � NOT TO SCALE (ABANDONED BETWEEN EW C_ NE_CTIO_NS) i 14 1 / AM W Garfield St -- I MOUND TRENCH WITH 6" a i NATIVE TOPSOIL OR S 0+99 �� •sl> STA 0 0.00 SUBGRADE PREP. AS TIE INTO EXTG. 4" E SERV. \ i �IE IN 0 EX G. 4 FIRE ERV, 6 REQUIRED. N VICINITY MAP w/NEW 90' ORIZ. BEND y i EW 5' HO IZ. EEND Q TYPE 'A' OR 'B' TRENCH V BACKFILL AS PER PLANS - - 1 / W ST 0+92 i GL NOTE: SLOPING, BENCHING w ,� W 22.5' �� / �i OR SUPPORT SYSTEMS C-� RIZ. BEND to6� i SHALL CONFORM WITH 6.5' Min. N GENERAL NOTES: O.S.H.A. CONSTRUCTION 7.5' Max. W a STA 0+87 / / STANDARDS FOR :4 J -,NEW 11.25' / i" � 1.ALL CONSTRUCTION WILL CONFORM TO MPWSS, (LATEST)EDITION, EXCAVATIONS. WW F' i AND COB MODIFICATIONS TO MPWSS. is r F' 0� ��HOT Z. BEND / SELECT TYPE 1 BEDDING ^"s' a° l / MATERIAL PLACED IN 6" `� a� 6 p ply T 8.0, / 2.ANY EXISTING OR NEW VALVES WHICH CONTROL THE COB's WATER a h Y R O i LAYERS AND COMPACTED AS ' '" / i - SUPPLY SHALL BE OPERATED BY COB PERSONNEL ONLY. xo � SPECIFIED IN SECTION 02221 i i _ // MINIMUM OF 24 HOURS PRIOR TO THE BEGINNING OF ANY WORK 3.THE CONTRACTOR SHALL NOTIFY THE WATER DEPARTMENT A (MPWSS) - TYPE 1 PIPE BEDDING -- �� PLACED IN 6" MAX. LAYERS „ " a w �-1 N O --- ----------- 4.CONTRACTOR SHALL FIELD-VERIFY LINE AND GRADE OF EXISTING AND COMPACTED O�'r CONNECTIONS. THOROUGHLY C) STA 0+51.5 - TYPE 2 PIPE BEDDING TRENCH WI TH O.D. of _ NEW CONCRETE O 5.CONCRETE THRUST BLOCKING AT ALL FIRE SERVICE JOINTS. WHERE REQUIRED FOR SOFT PIPE PLUS 2' MIN. SIDEWALK NEW 90-�0611Z. END TRENCH WIDTH=3.5' 8, j/j OR UNSTABLE FOUNDATION NEW ELEC. & GAS J _cqe ---- --- U G , "" F i NOTE: WHERE TRENCH PASSES THROUGH EXISTING PAVEMENT THEW EXTG, 1 PAVEMENT SHALL BE CUT ALONG A NEAT VERTICAL LINE A MINIMUM y z a SOLAR PANEL OF 12" FROM THE EDGE OF THE TRENCH OPENING. WHERE NEAT LINE d _ S LESS THAN 3' FROM EDGE OF EXISTING PAVEMENT OR CURB AND W d4 _ ___ GUTTER SECTION, REMOVE AND REPLACE ENTIRE PAVEMENT SECTION F w W -I BETWEEN TRENCH AND EDGE OF PAVEMENT. y3 PER CITY OF BOZEMAN STANDARD DRAWINGS NO. 02221-1 °w m w l WATER LINE TRENCH J W W ~ w � 4856-- C4.0 Not To Scale W Q FIRE SERVICE PLAN VIEW �) STANDARD THRUST BLOCK DIMENSIONS FOR VALVES R 0OR WOE PS) 150 P9 200 PSI250 PSImo P9 SIZE SIZE A° re° °C. A° re° °C' A° re° °C' A° re° °C' A° T .C. 4—in FIRE SERVICE PROFILE 7/4' 6°-8" 2-0" 2-0" 2-0" 2-0" 2-0" 2-0" 2-0" 2-0" 2-0' 2-0" 2-0" 2-0" 2-0" 2-0" 2-6" 7/4' 10' 2•-0" 2•-0" 2•-0" 2•-6" 2•-6" 2•-0" 2•-9" 2•-6" 2•-6" 7•-0" 7•-0" 7•-C 7•-6" 7•-C 7•-0" 4870 HORI ONTA SCAL 1" 10' 4870 7/4° 11° 1•-7" 1•-0" 1•-0" 3•-0" 3•-0" 2•-8" 3•-C 3•-C 3•-C 4•-7" 7•-C 7•-C 5•-0' X•0" 7•-C v '(�+I VE TICAL SCALE' 1" 5' 1° 14° 2'-7" 2'-0" 2'-4" 7•-C 3•-0" 7•-C 4•-0" 7•-C 7•-C 4•-6" 4•-0" 4•-0" 5•-6" 4•-0" 4•-0" O �j 1 I/8° 16° 7•-C 7•-C 7•-C 4•-4" 7•-0" 7•-C 4•-6" 4•-0" 4•-0" 5•-0" 4•-0" 4•-0" 6•-0' 4•-0' 4•-0" `V 1 I/4° 18° 7•-8" 7•-C 7•-C 5,_6" 7•-0" 7•-C 5,_0" 4,_0" 4,_0" 6•-4" 4,-0" 4,_0" 5,_9" 5,_0" 5,-0" 4865 4865 17/8` 24' 4-4" 4-0" 4-0" 6-6" 4-0" 4-0" 6-6" 5-0" 5-0" 6-6" 6-0" 6-0" 7-8" 6-0" 6-0" W N" N NOTE: PRESSURES SHOWN ABOVE ARE MAXIMUM WORKING PRESSURE IN SYSTEM. Ll j .. THRUST BLOCKING AND ANCHORS ARE REQUIRED ON ALL 6" VALVES AND LARGER r�l UNLESS SPECIFIED BY THE ENGINEER. 4860 —FINISH RADE 4860 STANDARD DIMENSIONS FOR THRUST BLOCKING E. 0. FITTING NES&PLUGS 90'BEND 45'BEND&OES REDUCERS&22 0.BEND SIZES A B A B A B A B 4° i'-8° i'-2' 1'-91 i'-61 1'-8" 0'-I0" I'-8" 01-6" 6 1 0° 1 0° 1 6 1 1 i 10 l 8 l 9 0 10 n 4855 s' MIN. co ER 4855 �� ^Y RE 8 1-8 1-6 7-2 7-0 2-6 2-0 I-9 1-6 ANCHOR /O° 7'-4° 7'-7° 4'-0° 7'-IO° 7'-01 2'-9" 2•-1" 2•-0" °�o O ^Y IZ 4•-0° Y-I0° 4'-8° 4'-8° 7'-8° 7'-7" 1•-8" 2•-7" EXTG. 4"0 .S. 6 .F. 4 L.F. 3 L.F. F 4" I4" 5•-6° 7•-IO" 6'-6" 5'-0° 4'-9° 3•-6" 3•-6" 2•-6" (� 4850 CL SS 5 DUC LE IR N PIP 4850 NOTE: THIS TABLE IS BASED ON 150 PSI MAIN PRESSURE and 2000 ESP SOIL W w BEARING PRESSURE WRAP ALL FITTINGS WITH POLYETHYLENE g UNDISTURBED ANCH ETL N w EARTH (TYP.) ANCHOR 4845 z o z w 4845 A m m w m L` NOTE: COAT RODS WITH "KOPPERS" ri N N BITUMASTIC No. 50 COATING OR EQUAL. DATE: _N o x - - B THRUST BLOCKING AND ANCHORS ARE 06.08.2016 REQUIRED ON ALL 6" VALVES AND REVISION: DATE: 4840 N• o u' 4840 l H LARGER UNLESS SPECIFIED BY THE 00 mN OON N. O /\ + +ti e ENGINEER. MEGA-LUG JOINT RESTRAINTS 0 suerBdmnL rn o N o o w B \ SHALL BE USED IN CONJUNCTION WITH r oa.rs.sors /\ CONCRETE THRUST BLOCKS. THRUST 0 a 3 ¢3 a 3 a 3\ /\ /A BLOCKS NOT REQUIRED ON TAPPING tnw H z VIZ U1Z to t~F 3 v V 0 � 4835 a 4835 TEE BEND VALVES. 0 O O O O CD O O ID O O O O O O O rn cn ID PER CITY OF BOZEMAN STANDARD DRAWINGS NO. 02660-1 &3 00 00 00 00 of of Do DO 00 00 00 00 00 00 ro W 0 Do D' D' D' D' 00 D' D' 00 00 00 00 00 00 00 `0 00 0 2 THRUST BLOCKING FOR WATER VALVES & FITTINGS z w 1+20 1+10 1+00 0+90 0+80 0+70 0+60 0+50 0+40 0+30 0+20 0+10 0+00 C4.0 Not To Scale meet No. a ��❑O