HomeMy WebLinkAbout16- Change Request - R&R Taylor Construction - Stiff Building RemodelEire.
R&R TAYLOR
CONSTRUCTION INC.
Change Request
To: Mike Gray
CITY OF BOZEMAN
411 EAST MAIN STREET
BOZEMAN, MT 59771
PO BOX 1230
BOZEMAN, MT 59771
Description: Proposal Request -1 Permit drawing changes
1775 LOVE LANE
BOZEMAN, MT 59718
Ph : 406-587-4451
Number: 1
Date: 4/14/2016
Job: 2016-054 STIFF BUILDING REMODEL
Phone:
We are pleased to offer the following specifications and pricing to make the following changes:
Please see attached pricing for the changes that were made to the plans as a result of the permit drawing review for the Alfred M.
Stiff Building. I have attached the Proposal request to this COR for reference.
This price also includes extra money for fire taping the ceiling between the lower and main level which was never brought up in the
bidding process, but was required by the building inspector, also there was
a request to insulate the wall that seperates the new conference room, and the server room, which also was not in the plans. There
is also a price from the electrician for extra work to modify conduit after it was
brought to our attention by the inspector that the ceiling height was to low. Everything was built per plan to that point. An additional
door the is to be installed on the main level to keep continuity through out the
building. Pricing also includes additional sprinkler heads that need to be installed in the "Old Platt Room" on the main level per Jack
Coburn. Lastly the additional dedicated circuits for the unit heaters in the upper
level are aslo included in this price. Please review and contact Chase Dyksterhouse if you have any questions or concerns.
Thank you,
The total direct cost to perform this work is............................................................................................... $12,155.60
(Please refer to attached sheet for details.)
Overhead $12,155.60 8.47% $1,029.00
Profit $12,155.60 4.23% $514.00
1% GRT $10,895.00 1.18% $129.00
Total: $13,827.60
If you have any questions, please contact me at.
Submitted by: Approved by:
Date:
Cc:
Page 1 of 2
R&R TAYLOR
CONSTRUCTION INC.
Change Request 1 Price Breakdown
Continuation Sheet
Description: Proposal Request -1 Permit drawing changes
1775 LOVE LANE
BOZEMAN, MT 59718
Ph : 406-587-4451
Description
Labor
Material
Equipment Subcontract
Other Price
DEMOLITION
$120.00
$120.00
FABRICATIONS
$300.00
$1,356.00
$1,656.00
FIBER INSULATION
$80.00
$300.00
$380.00
SHEET ROCK
$360.00
$300.00
$660.00
Taping
$500.00
$500.00
PLUMBING & HVAC
$200.00
$200.00
ELECTRICAL
$5,938.38
$5,938.38
WOOD DOORS
$80.00
$1,081.00
$1,161.00
FIRE SUPPRESSION
$1,540.22
$1,540.22
Subtotal: $12,155.60
Page 2 of 2
610
Owner City of Bozeman
Bozeman, MT 59715
Armitage Electric, Inc.
5555 Gooch Hill Rd
Bozeman, MT 59718
(406)585371 Phone
(408) 685-2804 Fax
Modification Proposal- PR # 1
Project: At Stiff Building
Contract. R&R Taylor
Location
Design changes
LINE
NO.
DESCRIPMU
cat 5 to cat 6
UNIT
MATERIAL COSTS
CITY OTY UNIT T07AL MANIIRS
LABORCO513
RATE
TOTAL
DIRECT
COSTS
LINE
TOTAL
1
CAT 6
In
4000 4 159 63600
41
5850
2.39850
3,03450
2
CAT 5
m
-4000 -4 73.44 -29376
•33.6
6860
-1.955.60
-2.259.36
3
48 port patch panel
e
1 1 138.35 13835
0
5860
000
138.35
4
24 port patch panel
e
2 2 49.6 9920
0
5850
000
9920
5
cat 6 jacks
a
24 24 8 192.00
12
58 50
70200
894.00
6
cat Se jacks
a
-24 -24 3.35 -8040
•6
58.50
-35100
431.40
7
cat 6 rapid tool
e
1 1 71.25 7125
0
5850
0.00
7125
8
0 01
0 0 0 000
0
5850
0,00
000
9
0 0
0 0 0 000
0
58.50
0.00
0.00
10
ACCES POINT BREAK ROOM
0
0 0 0 000
0
5850
0.00
000
11
m
401 0.04 0.00
58 50
0.00
000
12
cutin box
e
11 1 41 400
15
5850
8775
9175
13
cat 6 jacks
e
2 2 8 1600
0.35
5850
2046.
3648
14
coverr plate
e
1 1 0.65 065
0.1
58.50
5.85
6.50
15
cat 6 wire
m
50 0.05 159 795
1.65
5850
9653
104.48
16
0 0
0 0 0 0.00
0
5850
000
0.00
17
0
0 0 0 0.00
0
5850
0.00
000
18
ADD CONDUIT FOR TV
0
0 0 0 000
0
5850
0.00
000
19
1.5 Inch conduit
c
15 0.15 2.06 031
4
58.50
234.00
234.31
20
to
e
41 4 0.51 204
0.64
5850
3744
3948
21
lock rings
e
41 4 0.75 3 00
0.3
5850
17 55
2055
22
data rings
E
4 4 4 1600
1.1
58.50
64.35
8075--
23
4 SQUARE BOX
E
1 1 0.95 0.95
0.65
5850
38.03
3898
24
MUD RING
E
1 1 1.25 125
0.25
5850
1463
15.88
25
20 AMP RECECTICLE
e
1 1 2.89 2.89
0.3
5850
1755
2044.
26
cover plate
e
1 1 0.37 0.37
0.3
5850
1755
1792
27
R32 thhn
m
38 0.038 185 703
2.26
58.50
13221
139.24
28
0 0
0 0 0 000
0
5850
000
0.00
29
0 01
01 0 0 0.00
0
58501
0.00
0 DO
30
changed telling elevation break room
0
0 0 0 0.00
0
51150
000
0.00
32
3/4 emt couplings
e
5 5 1.37 6.85
0.25
5850
14.63
2148
33
labor
0
0 0 0 0.00
5.5
5850
32175
32175
34
D 0
0 01 0 000
0
68 50
0 00
0.00
35
0 0
0 0 0 0.00 1
0
5850
000
0.00
36
DOOR HOLDERS
0
0 0 0 0.00
0
5850
000
0.00
37
cert, holders, relay, design
e
1 1 834.5 83450
3
58.50
175.50
1,010.00
38
1/2 emt
c
100 1 28.65 2865
3
5850
17550
204.15
39
1/2 couplings
a
20 10 1.85 3700
0.6
5850
35.10
72 10
40
1/2 connect
e
6 6 1.26 756
0.6
58.50
3510
4266
41
wire mold single gang
e
2 2 5.47 10.94
2.5
5850
14625
157.19
42
#14 thhn
m
255 0.255 125 3168
4
5850
234.00
265.88
43
0 0
0 0 ol 0.00
0
58 50
000
0.00
44
Dedicated Heating Circuit
45
112 emt
a
40 1 28.65 2865
1.5
5800
8700
11565
46
1/2 couplings
e
5 5 1.85 925
0.3
5800
1740
2665
47
1/2 connect
e
2 2 1.26 252
0.2
5800
1160
1412
48
pl2thh2
m
180 0.038 0 000
2.5
58.50
146.25
146.25
49
Research Labor
0
0 0 0 D OD
2
58.50
117.00
117.00
SUBTOTALS:
1,822.87 63
Bond, Insurance
- -
-
3,084.88
Overhead
Profit
_
- -
0.10
0.05
_0.0_0_
0.00
4,907.76
49077
5,39852
26993
5.66845
_ 0.00
_S5,93838
S0.00
TOTAL $5.938.38
Armitage Electric, Inc, also requests an additional -day(s) extension of the contract period to perform [his additional work
Si ned: I Date:
tMinl4one
sping n
■
101 East Main — Studio One
Bozeman, Montana 59715
phone: 406.586.7020 fax: 406.586.8470
PROPOSAL REQUEST (CONTRACTOR) - SCOPE CHANGE
Project Name: Alfred M. Stiff Pro. Bldg. — Int. Alteration Project No.
Location: Bozeman, Montana PR No.
1417
Owner: City of Bozeman Contractor: R & R Taylor Construction, Inc.
121 North Rouse Avenue 1775 Love Lane
Bozeman, Montana 59715
Bozeman, Montana 59718
Please submit an itemized proposal for adjustments to the Contract Amount and/or Contract Time resulting from the
proposed modifications to the Contract Documents described below. This proposal shall include all costs associated
with the proposed change, such as materials, labor, overhead, and profit. This proposal shall be submitted to the
requestor within fourteen (14) calendar days of the date given below.
PROPOSED MODIFICATIONS:
1. Lower Level Scope Changes: Remove one door and infill opening. Provide water service to
refrigerator location. Refer to Sheets D1 .0, A1.0, A4.0, and MP2.0.
2. Main Level Scope Changes: Provide and install two safety gates in stairwells. Refer to Sheet A1.1
and Detail 11/A4.0. (Note: Provide a proposal to provide and install two gates as shown in Detail
1 1 /A4.0. Provide a second proposal to provide and install two gates as shown in Detail 12/A4.1,
complete with hold -open hardware and electrical work required to connect safety gates to fire alarm
3. Low Voltage Cabling: Eliminate Cat 5e cabling. All horizontal data and voice cabling to be Cat 6
with patch panel terminations to work with Owner's existing VolP system. Refer to revised Page
271500-4.
ATTACHMENTS:
ThinkOne
REQUESTED BY (CONSULTANT)
Cover Sheet, D1.0, A1.0, A1.1, A4.0, MP2.0, and Page 271500-4.
Jon Wirth
AUTHORIZED AGENT
2-29-16
DATE
If this proposal is accepted, the Owner will issue a Change Order to incorporate the proposed modifications into the
Contract.
ALFRED M. STIFF PROFESSIONAL BUILDING
INTERIOR ALTERATION
2.3 COPPER WIRE AND CABLES
A. Horizontal Data and Voice Cabling - All building data and voice cable shall consist of
listed, category 6, non- plenum, unshielded twisted pair (UTP), 4 -pair, 24 AWG solid
copper wires. The insulation and jacketing shall be type CM. Outer jacket shall be
blue. Under -carpet wiring and flat wiring are not allowed.
C. Multi -Pair Voice Cable — Multi -pair telephone cable shall be 22 AWG solid annealed
copper conductors with low density polyethylene jacket, non -plenum rated.
2.4 EQUIPMENT, TERMINATIONS, AND CONNECTING HARDWARE
A. All horizontal copper data and voice cable shall terminate at patch panels. Patch
panels shall be rated Category 6 and shall be equipped with rear cable manager,
icon/label holders, designation labels, cable ties and mounting hardware. Patch
panels shall be equal to Siemon HD6 series. Patch panel quantities shall be per the
plans.
C. Equipment racks shall be 84" x 19", aluminum, with quantity and accessories per the
details on the plan. Equipment racks shall be equal to Siemon RS.
D. Multi -pair voice cables shall be provided per the plans and shall be terminated onto 66
blocks in telecommuniucations closets where identified on the plans. Cables shall be
extended into Owner's PBX room for termination by Owner's representative. Provide a
minimum of 20' spare cable in PBX Room.
2.5 OUTLETS
A. RJ45 Couplers, for • and data, be • • • or equal.blue with Gernputer fer data.1
EaGh GOUpler shall OnGlude a GGIored iGGR tab, white with telephORe image fer vGiGe-__44
r
L"
7
Couplers shall be arranged in combinations of single, dual and blanks depending upon
the number required at a particular location per the contract drawings.
Faceplates shall be single -gang, plastic, with labels and label covers
series or equal.
Colors shall be white.
Siemon CT
VOICE AND DATA WIRING SYSTEMS 271500-4 COD-